Hydronic Heating

 

The Comfort Heat hydronic floor heating pipes can be used in a variety of floor heating installations and are suitable for large areas. The hydronic pipe is a flexible pipe system that operates using gas, solar or geothermal heat pumps;

 

In-Slab hydronic heating
The hydronic in-slab heating pipe is installed in the cement bed, clipped to the reinforcing steel. Hydronic in-slab heating has a slow response time and is installed in new constructions.

 

  APPLICATIONS :Direct & background underfloor heating
  PIPE TYPE :PEX-A
  DURABILTY :100% impermeable to oxygen and water vapour diffusion.
  PIPE SPACING :200 mm
  PIPE DIAMETER :16mm x 2 mm
  WARRANTY :10 years

 

 

DISTRIBUTION MANIFOLD
Supplies and controls water flow to the varies under floor pipe
circuits. Manifold includes individual flow adjustment and zone
control via a solenoid valve.

Max Temperature: 82.2°C
Rated Pressure: 0 .25 Mpa
Warranty: 5 years

 

 

 

 

 

In-Screed hydronic heating
The hydronic in-screed heating pipe is installed in the cement screed, beneath the tiles or any finished floor surface. Hydronic in-screed heating has a fast response time and can be installed when renovating.

  APPLICATIONS :Direct & background underfloor heating
  PIPE TYPE :5 layer composite pipe with aluminium core.
  DURABILTY :100% impermeable to oxygen and water vapour diffusion.
  PIPE SPACING :105 mm
  PIPE DIAMETER :11.6 x 1.5 mm
  WARRANTY :10 years

 

 

 

 

 

 

DISTRIBUTION MANIFOLD
Supplies and controls water flow to the varies under floor pipe
circuits. Manifold includes individual flow adjustment and zone
control via a solenoid valve.

Max Temperature: 82.2°C
Rated Pressure: 0 .25 Mpa
Warranty: 5 years