IN SCREED HEATING CABLE
TFS 17 TWIN
APPLICATIONS
The TFS 17 TWIN heating cable can be used in a variety of installations where a sand and cement bed is being used. The TFS 17 TWIN is suitable for large or small areas and is used in most wet areas. TFS 17 TWIN has a fast response time and will reach set temperature in approximately 1 - 2 hours.
CABLE TECHNOLOGY
As the TFS 17 TWIN screed cable is a twin conductor, there is no need to return the cable to the start of the installation. This makes installations very simple.
HEAT OUTPUT
The TFS 17 TWIN cable has a heat output of 175W per m² at 100mm spacing or 225W per m² at 75mm spacing. It is available in pre-determined lengths ranging from 10m up to 120m. Comfort Heat staff can select the correct cable length and spacing for your heated area.
INSTALLATION
The TFS 17 TWIN cable is installed before the cement screed, beneath any type of floor covering (generally tile). It is required that you cover the cable with a minimum of 20mm bed of screed. TFS 17 TWIN heating cable is held on the floor by either metal retaining strip or for wet areas, clipped to wire mesh (does not affect waterproofing), with a 100mm clearance from walls and fixtures. The TFS 17 TWIN can also be installed in a polished concrete floor.
SPECIAL REQUIREMENTS
Comfort Heat must be informed of any expansion joints in the slab. TFS 17 TWIN must not be installed over any expansion joints. For large areas multiple cables will be installed.